• Femoral component, CR,cemented,Shinvaunited,Femoral component, CR,cemented
  • Femoral component, CR,cemented,Shinvaunited,Femoral component, CR,cemented
  • Femoral component, CR,cemented,Shinvaunited,Femoral component, CR,cemented
  • Femoral component, CR,cemented,Shinvaunited,Femoral component, CR,cemented
  • Femoral component, CR,cemented,Shinvaunited,Femoral component, CR,cemented
  • Femoral component, CR,cemented,Shinvaunited,Femoral component, CR,cemented

Femoral component(CR)

Application scope: TKA
Specification: left/right
#1, #2, #3, #4,#5,#6
#1.5, #2.5, #3.5, #4.5, #5.5
Material: CoCrMo
Designed for cruciate-retaining total knee arthroplasty with optimized anatomy, bone preservation, and high-flexion performance.
  • Femoral component, CR,cemented,Shinvaunited,Femoral component, CR,cemented
  • Femoral component, CR,cemented,Shinvaunited,Femoral component, CR,cemented
  • Femoral component, CR,cemented,Shinvaunited,Femoral component, CR,cemented

Description

Compatible System Portfolio

Product Overview

The Femoral Component (CR) is designed for primary total knee arthroplasty requiring posterior cruciate ligament preservation.

Based on Chinese-specific anatomical characteristics, the femoral component incorporates optimized AP/ML proportional design and expanded sizing options to improve implant fit and reduce anatomical mismatch.

The component features a bone-preserving intercondylar design, optimized trochlear geometry, and high-flexion capability to support natural knee movement and long-term functional performance.

Product Features & Clinical Benefits

Chinese-Specific Anatomical Sizing Design

  • AP/ML ratio optimized according to Chinese patient anatomy.

  • Expanded size range with half-size options for improved femoral coverage.

  • Reduces overhang and improves component fit.

Bone Preservation Design

  • Optimized intercondylar notch design with increased fillet radius.

  • Minimizes bone resection and reduces the risk of intercondylar fracture.

  • Requires only 9 mm distal and posterior condyle resection.

Optimized Femoral Articulation Design

  • Curve-on-curve articulation design optimizes contact mechanics.

  • Improved femoral condyle and tibial insert radius matching reduces contact stress.

  • Supports reduced polyethylene wear.

Safe High-Flexion Performance

  • Optimized posterior condyle geometry supports high-flexion activities.

  • Rear-edge bevel design improves range of motion.

  • Supports knee flexion up to 155°.

Enhanced Patellar Tracking Design

  • Extended trochlear groove increases patellofemoral contact area.

  • Optimized patellar tracking helps improve anterior knee mechanics.

  • Supports smoother patellar movement during flexion and extension.

    Surgical Applications

    Indications:

    • Primary Total Knee Arthroplasty (TKA)

    Surgical Technique:

    • Cruciate-retaining (CR) procedure
    • PCL retained or selectively sacrificed according to surgical requirements

    Typical clinical applications include:

    • Primary knee osteoarthritis
    • Degenerative joint disease
    • Knee deformity requiring total knee replacement

    Specifications

    Parameter Description
    Product Type Femoral Component (CR)
    Application Primary Total Knee Arthroplasty
    Design Type Cruciate-Retaining
    Ligament Compatibility PCL Retained / Selectively Sacrificed
    Size Options 11 sizes including half sizes
    AP/ML Ratio 0.93–0.95
    Flexion Capability Up to 155°
    Bone Resection 9 mm distal and posterior condyle resection

    Available Sizes:

    Size AP (mm) ML (mm)
    #1 52 56
    #1.5 54 58
    #2 56 60
    #2.5 58 62
    #3 60 64
    #3.5 62 66
    #4 64 68
    #4.5 66 70
    #5 68 72
    #5.5 70 74
    #6 72 76

    Product Value & Purchasing Information

    System Compatibility & Complete Solution

    • Designed for integration within the XU-Knee Primary System.
    • Compatible with CR tibial inserts.
    • Supports flexible surgical approaches and balancing strategies.

    Product Quality & Reliability

    • Anatomical design improves implant fit.
    • Bone-preserving geometry supports conservative reconstruction.
    • Optimized articulation contributes to reduced wear performance.

    Supply & Delivery Support

    • Stable manufacturing capacity and long-term supply assurance.
    • Comprehensive technical documentation support.
    • Available product information includes:
      • Product specifications
      • Sterilization information
      • Product labeling
      • Batch traceability documentation

     

Leave a message
FirstName*
LastName*
Email*
Message
Verification Code*
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.