• Anatomical Femoral Shaft Fracture Plate,Shinvaunited,Anatomical Femoral Shaft Fracture Plate
  • Anatomical Femoral Shaft Fracture Plate,Shinvaunited,Anatomical Femoral Shaft Fracture Plate

Anatomical Femoral Shaft Fracture Plate

No.4032021
Material: TA3G Pure titanium, TC4 titanium alloy
Application: For the treatment of femoral fractures
  • Anatomical Femoral Shaft Fracture Plate,Shinvaunited,Anatomical Femoral Shaft Fracture Plate

Description

Product Introduction

The Femoral Locking Compression Plate is designed for internal fixation of proximal femoral fractures, providing stable fixation through a locking screw system.

The plate incorporates 20° conical locking holes for angular-stable screw fixation. Combined with ball-head screws, the system allows appropriate screw positioning and fixation according to the fracture configuration.

The plate is anatomically contoured to the proximal femur, with a low-profile design that helps reduce soft tissue irritation and improve plate-to-bone conformity.

Features

• 20° Conical Locking Holes: Provide angular stability and secure engagement between the locking screws and plate.

• Ball-Head Screws: Allow flexible screw positioning and help maintain a secure fixation construct.

• Self-Tapping Screws: Sharp cutting edges facilitate screw insertion into the bone.

• Anodized Surface: Provides corrosion resistance and supports material durability and biocompatibility.

• Anatomical Design: Contoured to the proximal femur to improve fit and reduce interference with surrounding soft tissues.

Advantages

• Reliable Fixation: The locking interface provides a secure plate-screw connection with angular stability.

• Efficient Screw Insertion: Self-tapping screws facilitate insertion and simplify the fixation procedure.

• Reduced Soft Tissue Irritation: The low-profile design and rounded edges help minimize interference with surrounding tissues.

• Flexible Screw Positioning: Ball-head screws provide greater flexibility in screw placement according to fracture anatomy.

• Stable Fracture Fixation: The locking construct helps maintain alignment and limit unwanted movement at the fracture site.

Indications

• Proximal femoral fractures, including femoral neck, intertrochanteric, and subtrochanteric fractures.

• Complex proximal femoral fractures requiring angular-stable fixation.

• Fractures requiring secure fixation, stable alignment, and controlled compression.

Specifications

Model Number Spec.(mm) Compatible screws
  4032021 12 Holes×229 5.0 mm Locking   Screw

   

4.5 mm Cortical Screw

14 Holes×265
16 Holes×300
Leave a message
FirstName*
LastName*
Email*
Message
Verification Code*
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.